IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 20197310 is a genuine OEM air-proving pressure switch for the GMH950904CXAB gas furnace and compatible Goodman/Amana models. Rated at -0.60 inches water column (WC) and normally open (NO), it confirms the induced-draft blower is establishing proper venting before the control board allows ignition. When the inducer pulls the correct negative pressure, the switch closes and the ignition sequence proceeds — a core safety interlock that prevents firing without adequate flue draft.
Pressure-switch set point is safety-critical and model-specific. The genuine Goodman -0.60" WC switch is calibrated to this furnace's inducer and venting design, with the correct hose barb and NO contacts. A generic switch with the wrong set point or action can prevent ignition or, dangerously, allow firing with poor venting. Match the exact set point — OEM guarantees it.
Easy–Moderate (2/5). Shut off power and gas, disconnect the sensing hose and the two wire leads, remove the mounting screw, and install the replacement. Confirm the hose is clear of condensate. Restore power and verify the furnace lights on the first call for heat. About 20 minutes.
Never bypass a pressure switch to force ignition. If the new switch will not close, check the inducer, hose, and vent for blockage.