The Goodman 20197310 Pressure Switch is a genuine OEM air-proving control calibrated to -0.60" WC with a normally open (NO) contact set, built for the GMH951155DXAD furnace. It confirms that the inducer draft motor is establishing adequate negative pressure before the control board allows ignition. If venting is blocked, the trap is clogged, or the inducer is weak, the switch stays open and safely prevents the furnace from firing.
Pressure switches must match your furnace's exact set point and contact type. The OEM 20197310 is factory-calibrated to -0.60" WC; a generic switch with a different rating can cause false lockouts or permit ignition without proven venting — a serious safety concern. Always replace with the exact specification.
A quick swap for a technician — disconnect power, label and remove the wire terminals and the silicone sensing hose, unscrew the switch, and mount the replacement. Reconnect the hose without kinks, verify the set point matches, and confirm a normal ignition sequence.