IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 20197311 Pressure Switch is a genuine OEM safety control for the Goodman ACSH961155DXAA furnace and compatible models. This normally open (NO) switch is calibrated to trip at -0.60 inches of water column (WC). It confirms that the inducer/draft blower is establishing proper combustion airflow and venting before the control board permits the gas valve to open — a critical step that prevents unsafe firing if the vent is blocked or the inducer fails.
Pressure switches are application-specific by set point and polarity. The factory OEM 20197311 is matched precisely to this furnace's static pressure, ensuring reliable proving and ignition. Generic switches with a different set point or contact configuration can cause intermittent no-heat lockouts, short cycling, or — worse — bypass a genuine venting fault. We strongly recommend OEM for any safety control.
Moderate (2/5). Disconnect power, label and remove the two electrical terminals and the rubber sensing hose, unscrew the mounting screws, and install the replacement in the same orientation. Reconnect the hose without kinks. Allow 20–30 minutes. If the new switch trips immediately, inspect the hose, inducer, and condensate trap for blockage before assuming a defective part.