IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 11177114 is an OEM negative-air-pressure switch for the AMVC950905DXBA variable-speed, 96% AFUE furnace. This normally-open switch proves that the induced-draft blower is establishing adequate negative pressure before the control board allows ignition. If venting is blocked or the inducer is weak, the switch stays open and locks out the burner — a core safety function that prevents combustion without proper draft.
Pressure switches must trip at an exact setpoint. The OEM -0.50" WC switch is calibrated to this furnace's inducer and vent design; a generic switch with a different setpoint can allow unsafe ignition or cause false lockouts. For a safety component, insist on OEM.
Easy–Moderate (2/5) — remove power, transfer the two spade wires and the sensing hose to the new switch, and mount. Verify no cracks in the tubing on restart.