IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman B1370126 Pressure Switch is a genuine OEM safety control for the GMPV125-5 gas furnace. Rated at -0.40" water column with normally open contacts, this switch verifies that the inducer draft motor is pulling adequate negative pressure before the control board permits ignition. If venting is blocked or the inducer fails, the switch stays open and locks out the furnace — a critical protection against flue-gas spillage.
The OEM B1370126 is calibrated to Goodman's exact -0.40" setpoint and uses the correct hose-port and terminal layout. Generic switches with a mismatched setpoint can cause nuisance lockouts or, worse, allow operation under unsafe draft conditions. On a combustion safety device, the OEM part is the right choice.
Easy (2 of 5). Disconnect power, remove the pressure hose and two spade terminals, unscrew the switch, and reverse to install. A multimeter helps confirm operation. Always verify draft after replacement.