The Goodman 20197312 air pressure switch is a factory-original draft-proving control for the GKS90905DXAA gas furnace. It confirms that the inducer (draft) motor is pulling proper combustion airflow before the ignition sequence begins. If venting is blocked, the trap is clogged, or the inducer is weak, the switch stays open and the control board safely aborts ignition — a core safety interlock on every condensing furnace.
Pressure switches are calibrated to a precise trip point, and the -0.37" WC rating on this genuine Goodman OEM part is matched to your furnace's vent design. Installing a switch with the wrong setpoint causes chronic no-heat lockouts or, worse, allows the burner to fire with inadequate venting. Always match the exact setpoint and NO/NC configuration — do not substitute.
Easy (2/5). About 15 minutes. Cut power, photograph the wire terminals and hose connection, remove the mounting screws, and transfer the rubber pressure tube to the new switch in the same position. Inspect the tube and port for condensate or debris before restarting — a plugged hose mimics a failed switch.
Disconnect power before servicing. Verify the setpoint stamped on the switch matches -0.37" WC.