The Goodman 11112501S is a genuine OEM air-pressure (draft) switch designed for the WGGE4324A070MAB gas furnace and compatible Goodman/Amana models. This normally-open switch verifies that the inducer draft motor is producing correct venting airflow before the control board allows the burners to ignite. When the switch senses the proper negative pressure of -0.33 inches of water column (WC), it closes and signals the board that it is safe to proceed — a critical safety function that prevents unsafe or incomplete combustion.
This is a genuine Goodman OEM switch, calibrated to the exact -0.33" WC trip point specified for your furnace. Generic aftermarket switches often carry loose tolerances that can cause nuisance lockouts or fail to protect against a blocked flue. For a combustion-safety component, matching the OEM setpoint is strongly recommended.
Easy (1 of 5). Replacement typically takes 15–20 minutes: cut power to the furnace, disconnect the two spade terminals and the rubber tubing, unscrew the switch bracket, and reverse the steps with the new unit. Always confirm no soot or moisture is present in the tubing. If you are not comfortable working around gas appliances, use a licensed HVAC technician.