Same-day shipping on orders before 3PM CST · 10,893 OEM Parts In Stock · Carrier · Bryant · ICP · Heil · Tempstar

Menu

Home Shop All Account Cart
MEDIUM URGENCY

York 11 Red Flashes — Limit Open Over 5 Minutes

11 red flashes

Limit switch open more than 5 minutes — usually failed blower.

Brand: York (Also covers Coleman, Luxaire)  |  Equipment: Gas Furnace

What This Code Means

11 red flashes means the limit switch has been open for over 5 minutes, indicating a persistent overheating problem (usually a failed blower).

Likely Causes (Ranked)

Most common

Failed blower motor

What: Blower not running, heat exchanger stays hot.

How to check: Listen for blower at heat call.

Fix: Replace motor.

Shop parts
Common

Failed blower capacitor

What: Capacitor failure prevents blower start.

How to check: Test capacitor with meter.

Fix: Replace capacitor.

Shop parts
Less common

Faulty limit switch

What: Switch stuck open.

How to check: Tech test.

Fix: Replace switch.

Shop parts

Diagnostic Steps

  1. Cut power
  2. Listen for blower at heat call
  3. Test capacitor
  4. Replace as needed

Frequently Asked Questions

Difference between York 4 and 11?
4 = brief limit trip; 11 = prolonged limit open, usually blower failure.
DIY?
Capacitor yes. Blower motor more advanced.
Same on Coleman?
Yes.

Related York Codes

Related Symptoms

Need More Help?

Try our interactive symptom diagnostic tool or browse York parts.

Home Shop Search Account Cart