IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 10123535 is a genuine OEM red-button manual reset rollout limit switch built for the AKSS920905DXAA gas furnace and related Goodman and Amana equipment. Rollout switches sit near the burner assembly and open the gas/ignition circuit the instant flame escapes the intended combustion path — a critical protection against blocked heat exchangers, cracked flues, or restricted venting. The distinctive red reset cap identifies this as the higher-temperature rollout limit versus the standard high-limit control.
The OEM 10123535 is factory-matched to Goodman's trip temperature and bracket geometry for a guaranteed fit and correct safety response. The Generic alternative delivers comparable rollout protection at a reduced cost, ideal for cost-conscious repairs where an exact-temperature match is verified. For flame-rollout safety, OEM is the recommended choice.
Easy (2/5). Kill power at the breaker, open the burner compartment, disconnect the spade terminals, remove the mounting screw, and install the replacement in the same orientation. Roughly 10–15 minutes with basic tools. If the switch tripped, diagnose the root cause — venting, airflow, or a cracked heat exchanger — before returning the furnace to service.