IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman B1370145 is a genuine OEM 300°F manual-reset flame rollout limit switch for the Goodman/Amana GMT115-5A gas furnace. This safety device is mounted at the burner box and shuts off the gas valve if flames roll out of the burner compartment — a condition caused by blocked flue passages, a cracked heat exchanger, or restricted combustion air. A tripped or failed rollout switch is a warning sign, not just a nuisance.
The OEM B1370145 is calibrated to Goodman's exact 300°F trip point and uses the correct bracket and terminal orientation for a bolt-in fit. Because this is a life-safety control, we do not recommend generic or mismatched-temperature substitutes — an incorrect trip point can allow unsafe combustion conditions to go undetected.
Shut off power, remove one or two mounting screws, transfer the wire terminals, and mount the new switch. Important: if this switch tripped, do not simply reset and forget it — have a technician inspect the heat exchanger and venting to find the root cause before returning the furnace to service.