The 10135604 is the genuine OEM relay used in the Goodman/Amana ASH130241AB 13 SEER, 2-ton heat pump. Relays like this one switch higher-current loads — such as the compressor contactor circuit, outdoor fan, or auxiliary components — in response to a low-voltage 24V signal from the control board or thermostat. When a relay's contacts pit or its coil opens, you'll see a component that won't energize even though the call for it is present.
The genuine Goodman relay matches the exact coil voltage, contact rating, and terminal footprint the factory harness expects. Substituting a generic relay with a different contact rating or pin arrangement risks nuisance failures, overheating, or a non-fitting plug — the OEM part simply drops in.
Relay replacement is a quick, low-voltage job: disconnect power at the outdoor disconnect, note or photograph the terminal wiring, unplug or unbolt the old relay, and transfer the connections to the new one. Most swaps take 10–20 minutes with basic hand tools. No refrigerant handling required.