The Goodman 10123535 Manual Reset Limit Switch (Red) is a genuine OEM high-limit safety control for the Goodman GKS90703BXAF gas furnace. The red push-button identifies this switch's specific trip-temperature calibration, distinguishing it from similar limit switches used elsewhere in the furnace. It opens the burner circuit on an overheat condition and must be manually reset, making it a first-line safety device that protects the heat exchanger and prevents fire hazards. Repeated tripping usually points to restricted airflow, a dirty filter, or a blower fault that should be corrected.
The colored button denotes a factory-calibrated trip point, so matching the correct part is essential. The genuine OEM Goodman 10123535 guarantees the right temperature rating and terminal layout. Generic replacements risk an incorrect cutoff temperature, which can compromise safety — we recommend OEM for this control.
Easy (2 of 5). Cut power to the furnace, unplug the spade terminals, remove the mounting screws, fit the new switch, and reconnect the wiring. About 15–20 minutes with a nut driver. Verify normal cycling and diagnose any recurring trips before returning the furnace to service.