IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 20162904 Primary Limit Temperature Control is the main high-limit safety switch for the Goodman/Amana AMH81005CXBB gas furnace and matching 80% AFUE models. Mounted on the heat exchanger bulkhead, this auto-reset control continuously senses supply-air temperature and interrupts the burner circuit if the furnace exceeds its safe operating limit — typically caused by restricted airflow, a failed blower, or a clogged filter.
Primary limits are factory-matched to each furnace's specific trip point and bracket geometry. The OEM 20162904 guarantees correct temperature calibration and a bolt-in fit. Universal snap-discs exist but require verifying trip temperature and often modifying the bracket — not recommended on a primary safety control.
Easy–Moderate (2/5). Remove the burner/blower access panel, disconnect two low-voltage leads, and swap the bracketed control. Cut power at the breaker first. If the new limit trips, address the underlying airflow restriction rather than jumping the switch.