IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 20162904 Primary Limit Temperature Control is a genuine OEM safety component engineered for the Amana/Goodman AMH80803BNBC 80,000 BTU gas furnace. This primary high-limit switch continuously monitors heat-exchanger and plenum temperature, cutting power to the gas valve if the furnace overheats due to restricted airflow, a dirty filter, or blower failure. A correctly functioning primary limit is essential for safe operation — a failed or nuisance-tripping limit is one of the most common causes of no-heat and short-cycling complaints.
OEM vs. Generic: This is the factory-specified OEM part with the exact trip temperature and bracket geometry your furnace was designed around. Generic universal limits may require bending mounting tabs or recalibration and can trip early — the OEM part drops in with no guesswork and preserves your equipment warranty.
Install difficulty: Easy (2 of 5). Remove furnace power, unplug the two spade terminals, remove two mounting screws, and swap. Typically a 10–15 minute repair for a homeowner comfortable working inside the burner compartment. Always confirm airflow and filter condition to avoid repeat trips.