IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 20162904 is a genuine OEM primary limit temperature control for the Goodman/Amana AMH80604BNBB gas furnace. Mounted on the heat exchanger/blower deck, this primary high-limit switch monitors supply-air temperature and opens the circuit to shut off the burners if the furnace overheats — typically from restricted airflow, a dirty filter, or a failed blower. It is the furnace's main overtemperature safety and directly protects the heat exchanger from thermal damage.
The OEM 20162904 uses the exact trip temperature, probe length, and mounting flange Goodman specified for this model. Universal limits with a different set point or insertion depth can cause repeated short-cycling on limit or fail to trip when needed. For a primary safety control, OEM calibration and fit are essential.
Moderate (3/5). Requires removing the mounting screws, transferring wiring, and confirming the sensing element seats in the correct airstream position. Address any airflow restriction (filter, blower, ducting) before returning to service. Shut off power and gas first; professional service recommended.