IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 20162904 is the genuine OEM primary high-limit temperature control for the Amana/Goodman AMH80603AXBD gas furnace and other compatible 80% AFUE models. This safety-critical switch monitors heat-exchanger and plenum temperature, cutting power to the gas valve if the furnace overheats due to restricted airflow, a dirty filter, or blower failure. A limit that has tripped permanently or drifted out of spec is one of the most common causes of short-cycling and no-heat calls.
The genuine OEM 20162904 is calibrated to the exact trip and reset temperatures specified by Goodman for this furnace family, so the burner sequence and blower timing behave as designed. Universal aftermarket limits often carry a different trip point or mounting footprint, which can nuisance-trip or fail to protect the heat exchanger. For a safety device, we recommend the factory part.
Easy (2/5). Typically two mounting screws and two spade terminals. Always shut off power and gas before servicing. If you are unsure whether the limit or the airflow is the root cause, have a licensed HVAC technician confirm the diagnosis before replacing.