The Goodman 20162904 Primary Limit Temperature Control is a genuine OEM safety switch for the Amana/Goodman AMEC800804BNAB gas furnace. This high-limit control continuously monitors the temperature in the heat exchanger/plenum and shuts off the burners if the furnace overheats — protecting the heat exchanger from cracking and preventing a fire hazard. If your furnace short-cycles, trips on high limit, or fails to fire, a faulty primary limit is a common cause.
The genuine OEM 20162904 is calibrated to the exact open/close temperature and mounting footprint specified for this furnace. Because this is a life-safety device, we strongly recommend OEM — a generic limit with a different trip temperature can allow dangerous overheating or cause nuisance shutdowns. Generic snap-disc alternatives exist at lower cost but must match temperature rating and bracket dimensions precisely; when in doubt, use OEM.
Easy to Moderate. Typically a two-wire, two-screw replacement once the burner compartment is opened. Cut power at the disconnect first, note wire orientation, and confirm the temperature rating stamped on the disc matches the original. Restore power and verify normal burner cycling after install.