IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 20162904 is a factory OEM primary high-limit temperature control for Goodman and Amana gas furnaces, including the AMH80804BXBA. Mounted on the heat exchanger bulkhead, it monitors supply-plenum temperature and shuts off the burners if the furnace overheats — typically caused by a dirty filter, weak blower, or closed registers. It is an automatic-reset control that closes again once temperature returns to a safe range.
Primary limits are matched to a specific trip temperature and probe length for each furnace model. The OEM 20162904 guarantees the correct setpoint and fit. A generic limit with the wrong rating can cause short-cycling on limit or fail to protect the heat exchanger — a safety-critical difference.
Moderate (2/5). Shut off power and gas, disconnect the two spade terminals, remove the mounting screws, and transfer the new control to the same position. About 20 minutes. After install, verify the blower and filter are clean so the limit is not masking an airflow problem.