IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 20162904 Primary Limit Temperature Control is a genuine OEM high-limit safety switch for the AMH80803BXBA gas furnace and compatible Goodman/Amana models. Mounted on the heat-exchanger bulkhead, it continuously monitors supply-plenum temperature and de-energizes the gas valve if the furnace overheats — typically from restricted airflow, a dirty filter, or a failed blower. It auto-resets once temperature returns to a safe range, protecting the heat exchanger from cracking.
The OEM 20162904 ships with the correct trip temperature and probe length for the AMH cabinet. Generic substitutes with a shorter probe or wrong setpoint can short-cycle the furnace on limit or fail to protect it. For a primary safety, OEM is the reliable choice.
Moderate (2/5) — Two screws and spade terminals, but the probe must seat in the correct airstream position. Shut off power and gas, transfer wiring one lead at a time, and address any airflow restriction that caused the trip.