The Goodman 0130F00035 is a genuine OEM primary limit switch — identified by its purple housing — for the WFD18070S3AXCB furnace. Mounted on the heat exchanger bulkhead, the primary limit continuously monitors supply-air temperature. If airflow is lost (from a dirty filter, failed blower, or closed dampers) and temperatures climb past the factory setpoint, the switch opens the circuit to the gas valve and shuts the furnace down, protecting the heat exchanger from cracking.
The purple color code corresponds to a specific factory-calibrated trip temperature. Installing the correct OEM 0130F00035 guarantees the furnace shuts down at the intended threshold. Generic switches or the wrong color-coded limit can trip too early (nuisance shutdowns) or too late (heat exchanger damage). For this safety control, match the OEM part exactly.
Easy (2/5). The limit switch mounts with two screws to the heat exchanger panel and connects with two spade terminals — about a 15-minute job with a nut driver. Disconnect power and gas before servicing. If the original switch tripped, diagnose and correct the airflow restriction before restoring operation.