The Goodman 20162901 is a genuine OEM primary high-limit switch designed as a direct replacement for the Amana/Goodman AMH80403ANBD gas furnace. This thermally-activated safety control monitors heat-exchanger temperature and opens the circuit to shut off the burners if the furnace overheats — protecting against restricted airflow, dirty filters, or blower failure. A failed limit switch is a common cause of a furnace that short-cycles or won't fire at all.
OEM 20162901 is calibrated to the exact open/close temperature setpoint specified for this furnace's heat exchanger. Generic snap-discs may carry a different trip temperature, which can either nuisance-trip during normal operation or fail to protect the unit. For a safety-critical control, use the OEM part.
Easy — Disconnect power at the breaker, remove the two mounting screws, transfer the wire connectors to the new switch, and remount. Typically a 15-minute repair for a homeowner comfortable with basic tools; otherwise call a technician.