The B1370189 is a genuine Goodman primary high-limit switch engineered as a direct replacement for GMT045-3B gas furnaces and related Goodman/Amana equipment. Mounted on the heat exchanger/plenum, this normally-closed control opens at roughly 200°F to interrupt the burner circuit and stop combustion if supply-air temperature climbs too high — the furnace's primary overheat protection against restricted airflow or a failed blower.
The genuine Goodman OEM switch is factory-calibrated to the exact 200°F trip point matched to this furnace's cabinet and airflow design. Generic replacements with a different rating or bracket can cause premature cycling on limit or allow the exchanger to overheat. For a life-safety component, OEM is the right choice.
Easy (1 of 5). Remove two screws, transfer the spade terminals, and mount the new switch in the same orientation. Shut off power and gas first; when in doubt, hire a licensed technician.