IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The genuine OEM Goodman 20162904 Primary Limit Temperature Control is the main high-limit safety switch for the VMSS960803BNAA gas furnace. Mounted on the heat-exchanger bulkhead, it continuously senses plenum temperature and opens the gas/ignition circuit whenever the furnace exceeds its safe operating limit — protecting the heat exchanger, blower, and ductwork from heat damage caused by low airflow. This auto-reset control closes again once temperatures return to normal, allowing the furnace to resume heating.
As the furnace's primary over-temperature protection, this control must trip at the precise factory-calibrated setpoint. This genuine Goodman OEM part guarantees the correct cutout and reset temperatures. Generic replacements with approximate ratings risk nuisance shutdowns or unsafe operation, so OEM is strongly recommended for this safety component.
Easy to Moderate (2 of 3). Held by one or two mounting screws with a two-wire connection. Cut power and gas before servicing. Confirm the underlying cause of any high-limit trip — usually a clogged filter or weak blower — before returning the furnace to service.