The Goodman 20162904 Primary Limit Temperature Control is a genuine OEM safety control for the AMEC800805DXAA gas furnace and compatible Goodman/Amana models. Mounted on the heat exchanger / plenum, this primary high-limit senses supply-air temperature and interrupts the burner circuit if the furnace overheats — typically from restricted airflow, a dirty filter, or a failing blower. As an auto-reset control, it closes again once temperatures return to normal, cycling the furnace off and on to keep the heat exchanger within safe limits.
The primary limit is factory-matched to the furnace's cabinet geometry and trip temperature. Because it directly protects the heat exchanger and occupants, we recommend the genuine OEM control — a generic substitute with a different set point can cause short-cycling or fail to protect against a cracked heat exchanger condition.
Moderate (2.5/5). Power off the furnace, disconnect the wire leads, remove the mounting screws, and install the new control in the same orientation. 15-20 minutes with a nut driver. Correct any underlying airflow restriction before returning the furnace to service.