IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 20162901 is a genuine OEM primary high-limit switch designed for the AMH80403AXBB gas furnace. Mounted on the heat-exchanger or blower deck, this temperature-sensing safety control monitors supply-air heat and opens the gas circuit if the furnace overheats — typically from a dirty filter, failed blower, or restricted ductwork. When the temperature returns to normal, the auto-reset switch closes and allows the furnace to fire again. A furnace that short-cycles on limit or fails to heat is often traced to a faulty primary limit switch.
The genuine OEM 20162901 is matched to Goodman's precise trip and reset temperatures and mounting footprint, ensuring proper over-temperature protection and correct furnace cycling. Generic limit switches with mismatched set points can cause nuisance trips or, worse, fail to protect the heat exchanger. For safe, reliable operation, OEM is the correct choice.
A common DIY repair. With power off, remove the two wire terminals, unscrew the switch from the burner box or blower deck, and mount the new switch in the identical position with the sensing element in the airstream. Reconnect the wiring. Estimated time: 10-15 minutes. Check the filter and blower to rule out the root cause of overheating.