Restore proper combustion with the genuine Goodman 10716003 natural gas burner orifice, designed for the Goodman GMT140-5A gas furnace and other compatible Goodman/Amana equipment. The orifice (spud) threads into the manifold and meters the exact volume of natural gas delivered to each burner. A worn, corroded, or incorrectly sized orifice causes lazy yellow flames, sooting, delayed ignition, and reduced heating capacity.
Genuine Goodman orifices are machined to a factory-verified drill size that matches the furnace's rated BTU input. Generic or hand-drilled orifices risk over- or under-firing the appliance, which wastes fuel and can damage the heat exchanger. The OEM spud guarantees the correct, safe gas flow.
Moderate — requires shutting off the gas supply, removing the burner assembly, and threading the orifice into the manifold with a nut driver. Best performed by a technician comfortable with gas connections, followed by a leak check.
Always shut off gas and power before servicing. Verify no leaks with soapy water after installation. When in doubt, use a licensed HVAC professional.