The Goodman 10716003 is a genuine OEM natural-gas burner orifice (spud) precision-drilled for the ACVC90905DXAA high-efficiency gas furnace. The orifice meters the exact volume of natural gas delivered to each burner, setting the air-fuel mixture for clean, efficient combustion. A worn, corroded, or incorrectly sized orifice causes sooting, delayed ignition, yellow flame, or rumbling — so matching the OEM drill size to the furnace's rated input is critical.
The genuine Goodman orifice is drilled and gauged to factory tolerance for the furnace's BTU rating and manifold pressure. Generic or mis-drilled orifices alter the firing rate, hurting efficiency and risking unsafe combustion or CO production. For natural-gas applications, always install the exact OEM-specified orifice size.
Moderate (3/5). Threads into the gas manifold and takes 15–20 minutes per orifice, but combustion work should be verified by a licensed technician. Shut off gas and power, confirm the correct orifice for your fuel and altitude, and check manifold pressure after install.