The Goodman 10716005 Natural Gas Orifice (burner spud) is the genuine OEM metering jet that feeds the correct volume of natural gas to each burner on the ACES960804CNAA gas furnace. The precision-drilled orifice bore sets the firing rate, so using the factory-spec part is essential for proper input (BTU/hr), a clean blue flame, and safe, efficient combustion.
Replace an orifice that is enlarged, corroded, clogged with debris, or was swapped to the wrong size during a fuel conversion. Installing the correct OEM natural-gas orifice restores rated heating output and prevents sooting, lifting, or under-fire conditions.
Orifice drill size is the single most important spec on this part. A generic or mis-drilled spud changes the BTU input and can create a dangerous over- or under-fire condition. The OEM 10716005 is machined to the exact Goodman natural-gas bore for guaranteed correct input.
Moderate (3/5) — Threads into the manifold; about 20–30 minutes and should be set/verified by a qualified tech with a manometer. Shut off gas and power before service.