IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 10716005 Natural Gas Orifice is a genuine OEM burner spud sized for ACES960403BNAA gas furnaces and compatible Goodman/Amana models. The orifice meters the exact volume of natural gas entering each in-shot burner, setting the furnace's BTU input and flame quality. A worn, corroded, or incorrectly drilled orifice produces lazy yellow flames, sooting, low heat output, or over-firing — all of which waste fuel and stress the heat exchanger.
The OEM orifice is precision-drilled to the manufacturer's exact diameter for the rated input at standard manifold pressure. Generic orifices can vary by a drill size or two, throwing off the air/fuel ratio and BTU input. Using OEM keeps combustion within spec and protects warranty coverage.
Easy–Intermediate. Shut off gas and power, then unthread the old orifice from the manifold and thread in the replacement with thread sealant rated for gas. Confirm fuel type before installing — never use a natural-gas orifice on an LP conversion. About 15–30 minutes; use a licensed technician if unsure.