IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman B2589343 Natural Gas Burner Orifice is a precision-drilled OEM spud that meters natural gas into the burner of your GDS80904BNA furnace. Orifice bore size is matched to the furnace's rated input BTU and manifold pressure, so replacing a worn, clogged, or previously LP-converted orifice with the correct factory part is essential for safe, efficient combustion.
Orifice bore diameter directly controls the gas flow rate. A generic or incorrectly sized orifice can over- or under-fire the furnace, producing carbon monoxide, sooting, or nuisance lockouts. The genuine OEM orifice is drilled to Goodman's exact specification for the GDS80904BNA input rating.
Moderate — Gas and power must be shut off before removing the manifold or burners. A licensed technician should verify manifold pressure and perform a combustion/leak test after installation.