IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 10123535 is a genuine OEM red-cap manual reset limit switch (flame rollout / high-limit safety) built for AMH950905DXAD high-efficiency gas furnaces. The red button identifies its higher trip-temperature set point within the furnace's layered safety system. This normally-closed thermal switch opens the burner control circuit on excessive heat or flame rollout, shutting the unit down to protect the heat exchanger and prevent fire. It latches open until manually reset, ensuring a technician inspects the cause before the furnace can fire again.
Note the red color: this switch has a specific trip rating that differs from similar-looking black or white limit switches on the same furnace. The genuine 10123535 guarantees the correct set point for its location. Substituting a switch with the wrong trip temperature can defeat the furnace's tiered safety design, so always match the OEM part and color code exactly.
Easy (2/5). Pull the two spade connectors, unbolt the switch from its bracket, install the red replacement in the same position, and reconnect. Roughly 15 minutes with a nut driver. Cut gas and power first, and diagnose the root cause of the trip before returning the furnace to service.