The Goodman 10123529 Manual Reset Limit Switch is the genuine OEM flame-rollout safety control for the VMES800604BXAA gas furnace. It monitors for abnormal heat at the burner box and shuts off the gas valve if a rollout or overheat condition is detected, requiring a manual reset before the furnace can restart — a critical safeguard against unsafe operation.
This OEM switch is calibrated to Goodman's exact trip temperature and mounting footprint. Because it is a life-safety device, a generic substitute with the wrong trip point can either nuisance-trip or fail to protect against rollout. Always use the factory-specified control here.
Moderate (2/5). Power down, disconnect the two spade terminals, unscrew the switch from the burner bracket, and install the replacement. Confirm the manual reset button is engaged before restarting.