IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 10123533 is a genuine OEM manual-reset limit (rollout) switch and a direct-fit replacement for the GMH950904CXAA 96% AFUE two-stage furnace. Mounted on the burner box, it opens and shuts off gas and ignition if flame rolls out of the burner compartment or heat-exchanger temperatures exceed safe limits — a critical protection against overheating and cracked heat exchangers. Because it is manual-reset, a trip requires you to press the button, which is intentional: it flags a condition that should be investigated.
The OEM Goodman switch trips at the factory-specified temperature and uses the correct bracket and terminal geometry for a bolt-in fit. Generic switches may differ in trip temperature or mounting, compromising a safety device. We strongly recommend OEM for limit and rollout switches.
Easy (2/5). Kill power, note the two wire positions, remove the mounting screws, and swap the switch. Roughly 10–15 minutes. If the switch had tripped, diagnose the root cause (blocked flue, dirty burners, cracked heat exchanger) before returning the furnace to service.