The Goodman 10123535 is a genuine OEM red-body manual reset rollout limit switch built for the GMH950703BXAA gas furnace and compatible Goodman/Amana equipment. Mounted at the burner assembly, this flame-rollout safety switch senses abnormal heat outside the heat exchanger — a symptom of a blocked flue, cracked heat exchanger, or restricted combustion air — and shuts down the furnace to prevent fire and carbon-monoxide hazards.
The genuine Goodman OEM 10123535 is factory-calibrated to the precise rollout trip point required for safe operation. Generic substitutes may trip at the wrong temperature, causing either dangerous late shutdowns or frustrating nuisance faults. On a life-safety control like this, we recommend OEM only.
Rating: Easy (2/5). Straightforward bracket-and-terminal swap. Power and gas OFF before starting. Important: a tripped rollout switch usually signals a real combustion problem — if it trips again after replacement, stop and call a licensed HVAC technician immediately.