IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 10123529 Manual Reset Limit Switch is a genuine OEM safety control for the GDH80403AXBB and compatible Goodman 80% AFUE gas furnaces. This manual-reset rollout / high-limit switch monitors for abnormal heat or flame rollout in the burner compartment and cuts power to the gas valve if a dangerous overheat condition occurs, protecting the furnace and home.
Because it requires a manual reset, a tripped switch signals that a technician should inspect for the underlying cause — a blocked flue, cracked heat exchanger, or restricted airflow. A switch that fails open or won't reset must be replaced with the exact OEM part to preserve the furnace's safety chain.
Genuine Goodman limit switches are calibrated to the exact trip temperature the furnace was engineered for. Generic switches with the wrong set point can nuisance-trip or, worse, fail to trip. For a life-safety component, always use OEM.
Moderate — shut off gas and power, disconnect the two spade terminals, unscrew the switch, and mount the replacement. Diagnose and correct the root cause before returning the furnace to service.