IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 10123539 Manual Reset Limit Switch is a genuine OEM flame-rollout safety control for the Amana/Goodman AMSS920803BNAA gas furnace. Mounted on the burner assembly, it senses abnormal heat from flame rollout and immediately opens the gas-valve circuit to shut the furnace down. Because it is a manual reset device, it stays tripped until an operator presses the reset button — a deliberate design that flags a real combustion problem rather than silently cycling.
The OEM 10123539 is calibrated to the exact trip temperature specified for this burner box and uses factory terminal spacing and bracket geometry for a bolt-in fit. Generic replacements may trip at the wrong temperature or require bracket modification — risky on a life-safety control. Always match the OEM spec on rollout switches.
Moderate (2/5). Shut off power and gas, photograph the wiring, unbolt the old switch, transfer the two spade connectors, and mount the new one. A repeated trip after replacement indicates an underlying rollout condition (blocked flue, cracked heat exchanger) that must be diagnosed by a technician.