IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 10123529 is a genuine OEM manual-reset limit (rollout) switch for Goodman and Amana gas furnaces, including the AMS81205DXAC. This safety control opens the ignition circuit if flames roll out of the burner box or excessive heat is detected, shutting the furnace down to prevent damage. Because it is a manual-reset device, a tripped switch signals a real problem that must be investigated before pressing the reset button.
The trip temperature and terminal orientation of the OEM 10123529 are matched to Goodman's furnace design. Generic switches with a different set point can nuisance-trip or, worse, fail to protect the unit. The OEM part guarantees the correct safety threshold and a direct terminal fit.
Easy (1.5/5). Disconnect power and gas, remove the two mounting screws, transfer the spade connectors, and mount the new switch. Always diagnose why a rollout switch tripped — a cracked heat exchanger or blocked flue — before returning the furnace to service.