The Goodman 10123529 Manual Reset Rollout Limit Switch is a genuine OEM safety control designed for AMS80603AXAB gas furnaces and compatible Goodman/Amana models. Mounted on the burner assembly, it senses flame rollout — flames escaping the burner box due to a blocked heat exchanger or restricted venting — and immediately cuts power to the gas valve to prevent an unsafe firing condition. Because it is a manual reset device, it will not automatically restore heat until the underlying fault is corrected and the button is pressed, giving you a clear signal that service is needed.
OEM vs. Generic: Our OEM 10123529 switch is calibrated to the exact trip temperature Goodman engineered for this furnace, ensuring proper safety response. Aftermarket generics may use a different trip point or mounting footprint, risking nuisance trips or delayed shutdown on a genuine fault. For a life-safety component, we recommend OEM.
Install difficulty: Easy (1/5). Disconnect power, transfer the two spade wires, and unscrew/replace the switch. Always identify the root cause of a rollout trip before returning the furnace to service.