The Goodman 10123529 is a genuine OEM manual-reset limit (flame-rollout) switch for the AMH81155CXCB gas furnace and related Goodman/Amana models. This high-temperature safety device opens the ignition circuit and shuts the furnace down if it detects abnormal heat from flame rollout or a blocked heat exchanger, protecting the equipment and the home from unsafe operation.
Because this is a life-safety limit, the trip temperature must match the furnace's design exactly. The OEM 10123529 is calibrated to the correct cutout point and terminal orientation for your unit. A generic switch with the wrong setpoint can either trip prematurely (nuisance shutdowns) or fail to protect against a genuine rollout condition — never a place to substitute.
Easy (2/5). With gas and power off, remove the two spade terminals and the mounting screw, install the new switch in the same location and orientation, and reconnect the leads. If the switch had tripped, investigate the root cause (blocked flue, cracked heat exchanger, or bad inducer) before returning the furnace to service.