The Goodman 10123529 is a genuine OEM manual reset rollout limit switch engineered for the Amana/Goodman AMH80704BXCC 80,000 BTU gas furnace. This safety control monitors for flame rollout at the burner box and opens the ignition circuit if abnormal heat is detected, shutting the furnace down to prevent damage and hazardous conditions. Because it is a manual reset device, a tripped switch requires a technician to identify the root cause before pressing the red reset button — an important safety feature that flags an underlying problem.
The genuine OEM 10123529 is calibrated to the exact trip temperature specified for your furnace, guaranteeing correct safety response and a factory-matched fit. Aftermarket equivalents may vary in trip point or terminal orientation, which can cause nuisance trips or improper protection. For a safety-critical control we recommend the OEM part.
Easy — DIY friendly (10–15 min). Shut off power and gas, unplug the two terminals, remove the mounting screws, and swap in the new switch. Always diagnose why the original tripped before returning the furnace to service.