IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The 10123529 is a genuine Goodman/Amana manual-reset rollout limit switch, a direct-fit safety control for the Amana AMH80604BXBD 80% AFUE gas furnace. Mounted at the burner box, this normally-closed switch opens the 24V control circuit and shuts the furnace down if it senses flame rollout or excessive burner-area temperature — a critical protection against a blocked heat exchanger or venting problem. Unlike an auto-reset limit, it requires a manual button press to restore operation, prompting a technician to diagnose the root cause.
As a life-safety component, the trip temperature must exactly match the factory specification. The OEM 10123529 is calibrated for this furnace's rollout location. Substituting an uncalibrated universal switch can defeat the safety function, so genuine OEM is strongly recommended and, in many cases, code-required.
Easy (2/5). Two mounting screws and two spade terminals. If a rollout switch has tripped, always diagnose and correct the underlying cause (blocked flue, cracked heat exchanger, dirty burners) before resetting or replacing. Shut off power and gas before servicing.