IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 10123535 Manual Reset Limit Switch (Red) is the genuine OEM high-temperature safety cutout for GMH950904CXAF 95% AFUE furnaces. The red button identifies this as a specific temperature-rated rollout/limit control in the burner or heat-exchanger area. It opens the ignition circuit when it senses excessive heat — typically from flame rollout, a cracked heat exchanger, or blocked flue — and must be manually reset once the fault is corrected.
OEM (this part): Correct trip point (the red button denotes its specific rating), exact terminals, and verified fit. Generic: Cross-referenced switches can differ in temperature setpoint, risking unsafe operation or repeated lockouts. Match the OEM part exactly for rollout protection.
Easy (1/5) — roughly 15 minutes. Power off, unscrew the switch, move the two spade terminals, and mount the replacement. A repeated rollout trip signals a combustion or venting problem — have it inspected before restarting.