IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 10123535 is a factory OEM red-button manual-reset high-limit switch for the GMH950904CXAD 96% AFUE two-stage gas furnace. This normally-closed thermal safety control cuts power to the burners on an over-temperature condition. The red reset button distinguishes it from the companion 10123533 limit — the two switches carry different temperature calibrations and mounting locations within the burner/heat-exchanger assembly, so match the part number to your furnace's parts diagram.
The genuine Goodman switch is factory-calibrated to the trip and reset points specified for this heat exchanger. Substituting a generic switch — or the wrong-color/wrong-rating Goodman switch — can cause nuisance trips or defeat the intended safety margin. Always match the OEM part number and rating.
Easy (2/5). Two mounting screws and two spade terminals; roughly 15–20 minutes with basic hand tools. Disconnect power and gas first, and address any underlying airflow restriction before restoring operation so the safety doesn't re-trip.