The genuine OEM Goodman 10123535 red manual reset limit switch is a direct-fit safety component for the Goodman GMH950704CXAC 96% AFUE gas furnace. The red button identifies its specific trip-temperature calibration. This high-limit / rollout switch senses overheat and flame-rollout conditions and de-energizes the gas valve, holding the furnace off until manually reset to protect the heat exchanger and surrounding cabinet.
The red button denotes a distinct set point, so it is essential to match the exact OEM part rather than a generic equivalent. The OEM 10123535 is factory-calibrated to Goodman's specification, ensuring the switch trips at the correct temperature every time. Mismatched aftermarket switches risk nuisance shutdowns or unsafe operation.
Moderate (2/5) — Remove two mounting screws, transfer the spade connectors, and reinstall in the same orientation. Roughly 15–20 minutes.
Disconnect gas and power before servicing. Repeated trips indicate an underlying fault — have a licensed HVAC technician inspect the system.