IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 10123535 Manual Reset Limit Switch (Red) is a genuine OEM high-temperature safety control for the GKS90904CXAF gas furnace and related Goodman/Amana equipment. The red button designates it as a manual-reset device at a specific trip point in the burner/heat-exchanger safety chain. When temperatures exceed the rated cutout, the switch opens and shuts down the gas valve, then holds open until an operator presses the reset — ensuring the fault is investigated before the furnace fires again.
The genuine 10123535 is calibrated to Goodman's exact factory trip temperature — the red housing signals a different setpoint than similar-looking switches, so substituting the wrong color or a generic equivalent can cause either nuisance lockouts or a dangerously delayed trip. OEM ensures correct calibration, proper fit in the factory bracket, and preserved safety certification.
Easy (2/5) — Cut gas and power, note terminal orientation, swap the two spade connectors, and remount. Confirm the replacement matches the red setpoint of the original. Diagnose the cause of the overheat (restricted airflow, dirty filter, failed blower) before restoring service. Professional verification recommended.