IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The genuine OEM Goodman 10123535 is a red-button manual reset limit switch and a direct-fit replacement for GKS90904CXAG gas furnaces and compatible Goodman/Amana equipment. Like all manual reset limits, it is a safety cutout that opens the low-voltage control circuit on an overheat or flame-rollout event and holds the furnace off until the button is manually pressed. The red button typically denotes a specific trip temperature in the furnace's protection scheme, so match the part number rather than the color alone.
The OEM 10123535 guarantees the correct trip temperature, bracket, and terminal layout for this furnace. Because a limit switch protects against fire and heat-exchanger damage, we recommend the factory OEM part over universal substitutes — a mismatched setpoint defeats the safety function.
Easy (1 of 5). Kill power at the disconnect, transfer the two spade wires, and swap the switch on its mounting screws. If the switch trips again after resetting, stop and diagnose the root cause (airflow restriction, dirty filter, blower failure, or flame rollout). Never jumper or defeat a manual reset limit to keep the furnace running.