The Goodman 10123535 is a genuine OEM red manual reset high-limit switch designed for the AMH950905DXAE gas furnace and related Goodman and Amana models. The red-button reset identifies this as a secondary or rollout safety limit in the furnace's layered protection system. It monitors for excessive temperature or flame rollout and cuts the burner circuit to prevent damage, requiring a manual reset so faults are never silently cleared.
As a genuine OEM component, the 10123535 is factory-calibrated to the precise trip point your furnace requires. Generic substitutes often lack the exact temperature rating and terminal configuration, risking nuisance shutdowns or compromised safety. For rollout and limit protection, always choose OEM.
Easy (1 of 3). Disconnect power, note terminal orientation, and swap using the existing mounting. A repeated trip signals a combustion or airflow problem that should be professionally diagnosed before resetting.