The Goodman 10123535 is a genuine OEM red manual reset high-limit safety switch for the AMH950704CXAB gas furnace. The red button denotes a distinct trip temperature within the furnace's safety chain — this switch guards a specific overheat/rollout zone and opens the control circuit on a fault, shutting the burner down to protect the heat exchanger. Like all manual reset limits, it holds open after a trip until it is physically reset, ensuring a genuine fault gets attention.
The red 10123535 and its companion switches carry different factory trip points — using the wrong color or a generic substitute installs the wrong setpoint into a safety circuit. The OEM part is calibrated exactly for its position on the AMH950704CXAB, so it protects when needed without nuisance-tripping during normal firing. For safety controls, always match the genuine part.
Moderate (2/5). Disconnect power and gas. Note the switch location and orientation, remove the mounting screws, move the spade connectors to the new switch, and remount flush. About 15–20 minutes. Confirm you are replacing the red switch with the correct red OEM part, and investigate why it tripped before restoring service.