IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 10123529 Manual Reset Limit Switch is a genuine OEM high-temperature safety control for the WGGE4530A090MAA furnace and compatible Goodman/Amana equipment. This manual-reset limit opens the ignition circuit if the furnace overheats — typically from restricted airflow or a blower fault — and stays open until manually reset, protecting the heat exchanger from thermal damage.
The genuine Goodman limit switch is set to the furnace's specified trip temperature and reset behavior. Generic manual-reset limits can carry a different cutout temperature, tripping too early (nuisance no-heat) or too late (unsafe). Because this device is the last line of defense against a cracked heat exchanger, install the OEM part with the correct temperature rating.
Easy (2/5). De-energize the furnace, note terminal positions, unscrew the old switch from the burner box or blower deck, and mount the replacement in the same location and orientation. Press the reset button after wiring. If the new switch trips again, diagnose the underlying airflow or combustion fault — don't bypass the limit. Cut power before servicing.
Genuine OEM part from NationalHVACParts.com. Verify your model before ordering — contact info@nationalhvacparts.com.