IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 10123529 Manual Reset Limit Switch is a genuine OEM safety control for the WGFM28115V5CXAA gas furnace and compatible Goodman/Amana models. Unlike an auto-reset limit, this manual-reset switch stays open after tripping and must be physically reset by pressing its button — a deliberate design that forces a technician to investigate the fault before the furnace can fire again.
Manual reset limits guard against flame rollout or dangerous overheating, usually caused by a blocked flue, cracked heat exchanger, or restricted airflow. If your furnace trips repeatedly, replacing the switch is only part of the fix — the underlying cause should also be diagnosed.
OEM vs. Generic: This OEM switch is calibrated to the exact factory trip temperature and matches the original bracket and terminal layout. Because it is a life-safety control, we strongly recommend the genuine OEM part over aftermarket substitutes with unverified trip points.
Install difficulty: Easy (2/5). Cut power at the breaker, disconnect the spade terminals, remove the mounting screws, and install the new switch in the same orientation. Reset the button after installation. Under 20 minutes for most DIYers — but if it keeps tripping, call a professional to check the flue and heat exchanger.